FIREFIGHTER 1 FINAL EXAM AND PRACTICE EXAM 2024-2025 QUESTIONS AND CORRECT VERIFIED ANSWERS /100% PASS SOLUTION / ALREADY GRADED A+ What are two methods of raising a ladder to the vertical position? A. Rung raise and beam raise B. East raise and West raise C. Manual raise and mechanical raise D. One-person raise and two-person raise - ANSWER--D. One-person raise and two-person raise Firefighters must use care in checking attic spaces with blown-in insulation because: A. the spaces may be small and difficult to work in. B. some types of insulation can cause skin irritation C. embers can smolder in insulation for many hours before igniting D. heated surfaces will not be detected with thermal imagers - ANSWER--C. embers can smolder in insulation for many hours before igniting One attractive feature of the fire fighter drag is that it: A. can be done in a toxic environment without SCBA B. requires no equipment to carry out C. works just as well as a water-rescue technique D. can be used when the victim is heavier than the rescuer - ANSWER--D. can be used when the victim is heavier than the rescuer The movement of heat through a steel beam to an