TMRR, biocides and antimicrobial coatings may be used only if: {Ans: 1. Their use is specified in a mold remediation protocol. 2. They are registered by the EPA for the intended use. 3. Their use is consistent w/ the manufacturers labeling instruction.}How do you re-mediate less than 10 sf MOLD GROWTH on CONCRETE OR CINDER BLOCK caused by clean water. {Ans: -Wet Vac -HEPA Vac (Minimum Protection N-95, gloves, goggles) (No containment)}Purpose of Mold Assessment {Ans: The purpose of a mold assessment is to determine the sources, locations and extent of mold growth in a building, to determine the conditions that caused the mold growth, and to enable the assessment consultant to prepare a mold remediation protocol.}TMRR, signs advising that mold remediation project is in progress shall bear the words: {Ans: Notice; Mold remediation project in progress.}How do you re-mediate a surface area of 100 sf of Mold Growth on WOOD SURFACES? {Ans: -Wet Vac -Damp Wipe -HEPA VAC -Discard -(FULL protection gloves, disposable full body clothing, headgear, foot coverings, a full-face respirator with HEPA filter.) -(FULL Containment two layers of fire-retardant polyethene sheeting within an airlock chamber. Maintain area under negative pressure with HEPA-filtered